Loading...

PTFE Thermocouple Wires & Compensating Cables


Home / Products/ PTFE Thermocouple Wires & Compensating Cables




PTFE Thermocouple Wires & Compensating Cables



A pair of different wires e.g. Nickle-Chromium, Ni-Al,Iron Contestant,NIR Contestant etc. as per DIN43760 standards is made in twin flat or round. From to make thermocouple leads being for accurate temp measuring and controls.As accurate and economial way over conventional insulations. The wires may be designed &manufactured as per customer specific requirements.



COLOR CODE & INITIAL CALIBRATION TOLERANCES FOR THERMOCOUPLE WIRE :

Thermocouple Type ANSI Color Code Initial Calibration Tolerances
Wire Alloys Calibration +/- Conductor Overall Temperature Range Standard. Limits Special Limits
Iron(+) vs. Constantan 1 TM(-) J White/Red Brown 0°C to + 285°C
285°C to +750°C
±2.2°C
±.75%
1.1°C
±4%
Chromel TM(+) vs. Alumerl TM(-) K Yellow / red Brown -20°C to + 110°C
-110°C to 0°C
+285°C to +1250°C
±2%
±2.2°%C
±2.2°C to ±.75%
±1.1°C%
±.4%
Copper(+) vs. Constantan TM .(-) T Blue/Red Brown -200°C to -65°C
-65°C to +130°C
130°C to +230°C
±1.5°C
±1°C
±.75%
±.8°C
±.5%
±.4%
Chromel(+) vs. Constantan TM .(-) E Purple/Red Brown -200°C to -170°C
-170°C to +250°C
250°C to +340°C
340°C to +900°C
±1°C
±1.7°C
±1.7%
±.5%
±1°C
±1°C%
±.4%
±.4%


Specification :

Condwtor Type J. K. T and E
Cote Insulation PTEE Fibreglass. Asbestos. PVC Ceramic. SS Braided
Core Colour ANSI Color Code
Max Temp PTEE (260t). Fibre-Glass (400"C)
Size of Conductor From AWG 10 to AWG 36 or As Per Customer
Shielding Material SS, Bare Copper, SPC, NPC or as ner Customer
Jacket Insulation PTFE, Fibre-glass, PVC Ceramic, SS Braided
Jacket Color ANSI Color Code